SUPEREX F-500

Lab scale supercritical CO2 extraction machine

01

  • 500 ml extractor column,

  • Working pressure up to 345 Bar,

  • Working temperature up to 70 °C,

  • Extraction in Continuous (Dynamic) CO2 flow mode,

  • Temperature control with PID algorithm,

  • Digital fully automatic pressure control,

  • Optional Co-solvent (10 ml/min) pump,

  • Easy sample loading,

  • Use of synthetic fabric baskets for solid samples, 

  • Changeable flow direction for liquid samples,

  • Possibility to take extract directly into Falcon tubes,

  • Liquid trapping feature in the secondary Falcon separator,

  • observable flow rate,

  • Independent electronic and mechanical pressure safety system,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor column against microbial attachments,

F-500.Video  

  • YouTube

SUPEREX F-500
Impregnation Module

1681458658807.png
  • 500 ml+250 ml extractor column,

  • Working pressure up to 345 Bar,

  • Working temperature up to 70 °C,

  • Continuous (Dynamic) CO2extraction in flow mode,

  • Temperature control with PID algorithmdead,

  • Digital fully automatic pressure control,

  • Optional Co-solvent (10 ml/min) pump,

  • Easy sample loading,

  • Use of synthetic fabric basket for solid samples, 

  • Changeable flow direction for liquid samples,

  • Possibility to take extract directly into Falcon tubes,

  • Liquid trapping feature in the secondary Falcon separator,

  • observable flow rate,

  • The material to be impregnated is loaded into the second column,

  • contact lenses etc. product-specific loading basket,

  • Independent electronic and mechanical pressure safety system,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor column against microbial attachments,

SUPEREX F-500
Micronization Module

  • 500 mL main extractor column,

  • 250 mL impregnation column,

  • Basket with shelf to place the material to be impregnated in the 250 mL column,

  • Micronization pump and nozzle for 500 mL column,

  • Stainless steel basket where micronized nanoparticles are collected,

  • Working pressure up to 345 Bar,

  • Operating temperature up to 70 °C,

  • Continuous (Dynamic) CO2 extraction in flow mode,

  • Temperature control with PID algorithmdead,

  • Digital fully automatic pressure control,

  • Easy sample loading possibility,

  • Use of synthetic fabric baskets for solid samples, 

  • Changeable flow direction for liquid samples

  • Possibility of taking extract directly into Falcon tubes,

  • Liquid trapping feature in the secondary Falcon separator,

  • Observable flow rate,

  • The material to be impregnated is loaded into the second column,

  • Contact lenses etc. Loading basket specific to products,

  • Flow can be provided between columns with valves,

  • Independently working electronic and mechanical pressure safety system,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor column against microbial adhesion,

​

SUPEREX F-1000

Counterflow Supercritical Extraction System 
(Counter-Current Extraction System)

F-1000 Counter-Current Supercritical CO2 Extaction Machine
  • 1 Liter extractor column

  • Extra 0.5 liter extractor column,

  • With CO2 liquefaction system,

  • Working pressure up to 345 Bar,

  • Working temperature up to 70 °C,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor columns against microbial attachments,

  • Special design for extraction from liquid sample,

  • Extra liquid feed pump,

  • Instant visible flow rate on the flowmeter,

  • Temperature control with PID algorithm,

  • Digital fully automatic pressure control,

  • Easy sample loading,

  • Independent electronic and mechanical pressure safety system,

  • YouTube

SUPEREX SC-1000

Supercritical Extraction System

SC 1000 Supercritical Carbondioxide Extraction Machine
  • 1 Liter extractor column,

  • 2 separator columns,

  • With CO2 liquefaction system,

  • Working pressure up to 345 Bar,

  • Working temperature up to 70 °C,

  • Temperature control in separators,

  • CO2 recycling system,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor columns against microbial attachments,

  • Temperature control with PID algorithm,

  • Digital fully automatic pressure control,

  • Possibility to load samples with a stainless steel basket or a cloth basket,

  • Gas feeding or cyclone flow feature from the bottom to the separators,

  • Trap solution to the separators; water, alcohol etc. can be added.

  • YouTube

SUPER EX SC-1000 Optional Features

  • CO2 recovery system,

  • Adding extra extractor,

  • Adding extra separator,

  • Pressure control in separators,

  • Fully-automatic flow control/Automatic back pressure regulator(BPR),

SUPEREX SC-2000

Supercritical Extraction System

SC-2000 Supercritical carbondioxide extraction machine
  • 2 Liter extractor column,

  • Extra 0.5 Liter extractor column,

  • Working pressure up to 345 Bar,

  • Working temperature up to 70 °C,

  • With CO2 liquefaction system,

  • All surfaces in contact with food are stainless steel,

  • Smooth-honed reactor columns against microbial attachments,

  • Special design for aroma extraction from liquid sample,

  • Easy sample loading and cleaning process,

  • Three separators, two of which are pressure and temperature controlled,

  • Replaceable cyclone flow or bottom feeding apparatus in separators,

  • Trap solution, water, alcohol, etc. to the separators. can be added.

  • Digital Automatic back pressure regulator (BPR),

  • With CO2 recycling system

  • Optional CO2 recovery feature,

  • Temperature control with PID algorithm,

  • Gas feeding or cyclone flow feature from the bottom to the separators,

SUPEREX AERO-1000

Supercritical Drying System

Aero 1000 Supercritical Aerogel Drying System
  • YouTube
  • 1 Liter extractor column,

  • Large diameter extractor column designed for airgel drying,

  • 1 separator column,

  • Specially designed stainless steel baskets for loading sol-gel sample,

  • Working pressure up to 138 Bar,

  • Working temperature up to 70 °C,

  • Liquefaction unit for stable CO2 supply,

  • The separator column, where the alcohol placed with the sol-gel can be recovered,

  • Temperature control with PID algorithm,

  • Digital fully automatic pressure control,

  • observable flow rate,

  • Adjustable CO2 supply and discharge feature at low speeds,

  • Adjustable pressure rise-drop curve,

SUPEREXAERO-5000

Supercritical Drying System

  • 5 liter extractor column,

  • Extra 0.5 liter extractor column,

  • Large diameter extractor column designed for airgel drying,

  • The separator column where the alcohol put in with the sol-gel can be recovered,

  • Specially designed stainless steel baskets for loading sol-gel sample,

  • Working pressure up to 138 Bar,

  • Working temperature up to 70 °C,

  • Liquefaction unit for stable CO2 supply,

  • Full-automatic drying process (CO2 feeding and discharge, drying process is fully automatic),

  • Remote control via PC and smartphone,

  • Emergency warning lamp with sound and light, showing the instant status of the device,

  • Temperature control with PID algorithm,

  • Digital fully automatic pressure control,

  • observable flow rate,

  • Adjustable CO2 supply and discharge feature at low speeds,

  • It can be used in long drying processes (24-48 hours),

  • Adjustable pressure rise-drop curve,

bottom of page